Drilling Report

RNS Number : 6484P
Edenville Energy PLC
06 October 2011
 

6th October 2011

 

EDENVILLE ENERGY PLC ("Edenville" or the "Company")

 

10 Assayed Borehole Results, Rukwa Coal Project, Tanzania

 

Highlights:

·    Rukwa Coalfield - previously producing near-surface coalfield

·    Mkomolo and Namwele basins - primary targets for coal resource delineation

·    Initial Mkomolo diamond drilling underway:

o    19 boreholes completed to date, coal bearing strata identified over 6,500m lateral strike distance, depth in excess of 230m

o    11 boreholes assayed to date, 10 boreholes returned coal results

·    10 assayed borehole results reported today:

o    Calorific Values up to 26.40 MJ/kg range

o    Coal appears to be thickening to the north of the basin

o    Testwork underway to determine the washability parameters, including the % yield of coal at a specific quality

·    Drilling operations to mobilise to Namwele at completion of Mkomolo area

·    Objective: Rapidly define a JORC compliant coal resource and assess Rukwa suitability for near term, open pit coal production

Edenville Energy plc (AIM:EDL), the coal focused African energy exploration and development company, today announces new assay results from the resource delineation drill programme at the Rukwa Coalfield project in South Western Tanzania. Management believe the assayed results to be highly encouraging and will continue exploration drilling in order to build a JORC complaint resource at Rukwa.

 

Drilling operations commenced in late July 2011 at the Mkomolo Basin of the Rukwa Coalfield. To date 19 boreholes for 2,266.10m have been completed with coal bearing strata identified over a lateral strike distance of 6,500m and to a depth in excess of 230m. The coal bearing strata or Coal Measures remains open ended both along strike to the north and at depth down dip to the west. Once the Mkomolo Basin drilling is completed in October the drilling rig will move south to the Namwele Basin.

 

Assay Results (results tabled in appendix)

 

As the drilling has stepped northwards through the Mkomolo basin the coal, and Coal Measure sequences, are thickening. The latest hole, MK11-019, has intersected Coal Measures of 39m in thickness, within which 10 metres of coal rich horizons are present. The drilling programme and associated core handling procedures is being overseen by Dr. R. Lowman of Wardell-Armstrong International, a leading international consultant in the Coal Industry with a view of estimating the Coal Resources to international reporting standards before the end of the year.

 

The Raw Coal results from the additional 9 boreholes, all drilled vertically, with coal have calorific values of the coal rich horizons varying from some 20.24 to 26.40 MJ/kg (41 samples). The remaining samples of interbedded carbonaceous mudstones and sandstone between the coal rich horizons are of lower quality. Float and Sink Analysis test work is now being conducted on several of these intersections in order to determine the washability parameters, including the % yield of coal at specific quality.

 

The coal bearing strata, defined here as the Karoo Coal Measures, intersected by the boreholes comprises an interlaminated/interbedded sequence of coals and mudstones, which include coal rich horizons comprising a high proportion of coal. Borehole MK11-05 drilled in the extreme southern portion of the Mkomolo Basin, intersected a very thin coal unit of <5cms in contact with the underlying basement gneisses and therefore defines the southern limit to this area. The remaining nine boreholes reported today all intersected the Karoo Coal Measures with thicknesses varying from 1.78 to 18.45m within which the thickness of the coal rich horizons varies up to 8m.  

 

Edenville will continue with testwork and following conclusion of drilling at Mkomolo will mobilise the drilling team to the Namwele Basin of the Rukwa coalfield. The Company strategy is to rapidly establish a defined JORC resource at the primary Rukwa areas. Current indications are that the coal, with appropriate processing, is suitable for use for power generation. The predicted demand for electricity in the southern African region, particularly Tanzania, bodes well for the development of the project.

 

In accordance with the AIM Rules, the information in this announcement has been reviewed by Mark Pryor, Managing Director of Edenville Energy  PLC, a qualified geologist with over 25 years' experience and Dr. R. Lowman of Wardell-Armstrong International, a leading consultant in the Coal Industry with over 30 years' experience.

 

Commenting today Simon Rollason, Chairman of Edenville, said; "These latest results are very encouraging and significantly the drilling has shown that the Coal Measures increases in thickness as we head northwards away from the previously known coal outcrops at Mkomolo. The Coal Measures in this newly discovered extension remain open-ended to the north and will be investigated further once the current drilling is completed. I look forward to updating shareholders on progress as drilling continues and further results are received."

Contact:

Edenville Energy plc


Simon Rollason - Chairman
Rakesh Patel -
Finance Director
www.edenville-energy.com

 +44 (0) 20 7099 1940 



ZAI Corporate Finance Ltd


Ray Zimmerman/ Marc Cramsie

+44 (0) 20 7060 2220



Threadneedle Communications


Laurence Read/Richard Gotla

+44 (0) 20 7653 9855

 

 

 

 

APPENDIX I

Hole_ID

From (m)

To (m)

Interval (m)

Moisture (%)

Ash (%)

Volatile (%)

F.C. (%)

Sulphur (%)

Gross C.V. MJ/kg

Gross C.V. Kcal/kg

MK11-02

53.43

53.84

0.41

5.0

44

23

29

5.54

15.20

3,631

54.12

54.21

0.09

5.9

34

26

34

6.38

18.26

4,361

54.31

54.55

0.24

4.6

38

25

32

5.03

16.99

4,058

54.55

54.78

0.23

6.3

29

29

36

7.37

19.87

4,746

55.42

55.59

0.17

3.3

51

21

25

14.75

13.01

3,107

55.59

55.79

0.20

3.3

47

23

27

8.86

14.00

3,344

55.79

55.89

0.10

3.7

47

23

27

6.51

14.19

3,389

55.89

56.12

0.23

4.3

38

33

26

8.71

17.72

4,232

56.12

56.20

0.08

5.3

33

28

34

7.24

19.30

4,610

56.76

56.86

0.10

4.3

41

26

28

8.26

16.54

3,951

57.16

57.40

0.24

2.9

65

17

15

3.25

7.18

1,715

MK11-03

55.20

56.10

0.90

3.0

58

17

22

7.12

9.75

2,329

56.10

56.55

0.45

3.5

56

18

23

5.08

10.74

2,565

MK11-04

70.58

70.70

0.12

6.3

54

19

21

13.49

11.54

2,756

MK11-05

No significant interval

MK11-06

89.62

90.32

0.70

8.5

15

35

41

5.17

25.11

5,998

91.00

92.20

1.20

5.9

24

32

38

5.30

21.89

5,228

MK11-07

92.67

93.10

0.43

6.1

34

29

30

4.55

18.14

4,333

93.65

94.15

0.50

6.3

32

32

30

7.61

19.25

4,598

MK11-08

30.72

30.82

0.10

5.7

33

30

31

9.41

18.73

4,474

36.34

36.46

0.12

5.8

23

33

38

6.27

22.21

5,305

36.86

36.92

0.06

3.0

63

17

17

3.55

7.65

1,827

37.89

38.01

0.12

4.3

35

29

32

12.34

17.96

4,290

38.27

38.60

0.33

4.5

51

22

23

6.47

12.22

2,919

38.79

38.88

0.09

5.4

65

16

14

1.78

6.97

1,665

38.96

39.18

0.22

8.0

21

34

36

5.74

22.52

5,379

39.45

39.53

0.08

7.3

24

32

37

4.06

21.60

5,159

39.78

39.92

0.14

6.4

21

35

38

3.75

22.70

5,422

40.00

40.16

0.16

6.9

35

23

35

4.64

16.81

4,015

40.16

40.32

0.16

5.8

21

29

44

4.93

22.52

5,379

43.50

43.60

0.10

6.0

21

33

40

6.12

22.64

5,408

44.26

44.34

0.08

6.8

25

32

37

3.55

21.10

5,040

44.72

44.79

0.07

6.2

25

33

36

3.47

21.04

5,025

45.02

45.13

0.11

6.2

26

36

33

5.00

20.80

4,968

45.95

46.05

0.10

7.1

22

28

43

5.17

22.15

5,291

MK11-09

63.00

63.07

0.07

4.0

45

19

32

6.43

14.58

3,482

63.37

63.44

0.07

4.7

23

32

40

8.24

22.98

5,489

64.00

64.15

0.15

5.8

22

35

37

4.64

23.02

5,498

64.70

64.80

0.10

5.4

23

34

38

5.68

22.95

5,482

65.75

65.88

0.13

4.9

35

29

31

3.86

18.08

4,318

65.94

66.44

0.50

5.8

19

36

40

6.43

24.44

5,837

66.65

66.80

0.15

6.6

28

26

39

3.08

21.04

5,025

67.64

67.82

0.18

4.2

27

33

36

7.94

21.29

5,085

68.02

68.27

0.25

5.8

21

35

38

7.60

23.70

5,661

71.43

71.55

0.12

4.8

28

31

36

12.49

20.98

5,011

72.90

72.95

0.05

5.1

18

33

45

3.97

24.56

5,866

73.08

73.30

0.22

4.8

33

30

33

4.53

18.98

4,533

73.67

73.74

0.07

6.4

18

35

41

4.49

24.25

5,792

74.04

74.22

0.18

5.0

28

31

36

9.65

20.98

5,011

MK11-10

48.30

48.45

0.15

6.7

16

36

41

5.73

25.01

5,974

49.85

50.00

0.15

5.0

18

36

42

7.67

24.46

5,842

50.07

50.14

0.07

4.0

28

34

34

8.93

20.86

4,982

50.30

50.46

0.16

5.1

24

30

41

4.70

22.43

5,357

50.55

50.61

0.06

5.6

21

32

41

5.78

23.14

5,527

50.77

50.87

0.10

5.4

16

35

43

4.01

25.05

5,983

51.73

52.17

0.44

6.6

22

35

36

5.84

23.02

5,498

52.90

53.15

0.25

5.6

29

31

35

7.27

20.67

4,937

53.15

53.86

0.71

3.2

54

27

16

2.20

11.56

2,761

53.86

54.23

0.37

3.3

57

23

16

4.75

10.30

2,460

59.35

59.50

0.15

5.1

27

29

39

11.65

21.41

5,114

MK11-11

43.02

43.63

0.61

5.3

35

30

30

5.52

18.26

4,361

44.62

44.7

0.08

5.4

18

36

40

3.92

24.54

5,861

44.78

44.9

0.12

5.5

20

37

38

5.07

24.02

5,737

45.18

45.3

0.12

5.4

20

36

39

5.66

23.82

5,689

45.8

46.23

0.43

5.6

20

33

41

4.90

23.61

5,639

46.64

46.75

0.11

4.6

30

30

35

7.89

20.24

4,834

46.83

46.93

0.10

4.7

28

32

36

7.05

21.17

5,056

47.03

47.12

0.09

5.6

13

38

44

5.16

26.40

6,306

47.24

47.85

0.61

5.7

19

36

40

4.91

24.31

5,806

48.03

48.3

0.27

4.4

32

29

34

5.08

19.43

4,641

48.58

48.68

0.10

4.8

35

31

29

3.86

18.45

4,407

55.37

55.46

0.09

6.1

21

30

42

11.28

23.32

5,570


Results on air dried basis F.C. - Fixed Carbon, C.V. - Calorific Value








 


This information is provided by RNS
The company news service from the London Stock Exchange
 
END
 
 
DRLQELFBFBFBFBB
UK 100

Latest directors dealings