NCEPOD supports NICE guidance on CardioQ-ODM

RNS Number : 6783T
Deltex Medical Group PLC
09 December 2011
 



 

 

Deltex Medical Group plc

 

NCEPOD call for implementation of NICE guidance on CardioQ-ODM

 

9 December 2011 - Deltex Medical Group plc, the global leader in oesophageal Doppler monitoring ('ODM'), notes that the National Confidential Enquiry into Patient Outcome and Death ('NCEPOD') has today published its report on standards of surgical care in the NHS.

 

The report addresses a number of deficiencies in care commonly experienced by high risk surgical patients and makes recommendations to improve fluid management before, during and after surgery. The report calls specifically for the implementation of the National Institute of Health and Clinical Excellence ('NICE') Medical Technology Guidance that recommended CardioQ-ODM in NHS patients undergoing major or high-risk surgery and in high risk patients undergoing lower risk surgery:

 

"Better intra-operative monitoring for high risk patients is required. The evidence base supports the use of peri-operative optimisation and this relies on extended haemodynamic monitoring. NICE Medical Technology Guidance 31 relating to cardiac output monitoring should be applied."

 

CardioQ-ODM is the cardiac output monitoring technology recommended by NICE in its guidance of 30 March 2011.

 

1 National institute for Health and Clinical Excellence. Medical Technology Guidance 3. CardioQ-ODM (oesophageal Doppler monitor) 2011 http://www.nice.org.uk/guidance/MTG3

 

Ewan Phillips, Deltex Medical's Chief Executive, commented:

 

"NCEPOD's recommendation that the NICE guidance on CardioQ-ODM be implemented provides powerful clinical backing to the accelerated adoption of our products in the NHS. It follows the announcement on Monday that the NHS has decided to launch a national drive to get full implementation of fluid management during surgery into practice across the NHS."

For further information, please contact:-

 

Deltex Medical Group plc                                    01243 774 837

Nigel Keen, Chairman                                         njk@deltexmedical.com

Ewan Phillips, Chief Executive                             eap@deltexmedical.com

Paul Mitchell, Finance Director                            pjm@deltexmedical.com

 

Nominated Adviser & Broker

Arden Partners plc                                             020 7614 5900

Chris Hardie                                                       chris.hardie@arden-partners.com

Jamie Cameron                                                  jamie.cameron@arden-partners.com

Kreab Gavin Anderson                                        020 7074 1800

Robert Speed                                                     rspeed@kreabgavinanderson.com

Deborah Walter                                                  dwalter@kreabgavinanderson.com

 

Notes for Editors

 

About NCEPOD (www.ncepod.org.uk)

 

The National Confidential Enquiry into Patient Outcome and Death (NCEPOD) is an independent body to which a corporate commitment has been made by the Medical and Surgical Colleges, Associations and Faculties related to its area of activity. Each of these bodies nominates members on to NCEPOD's Steering Group.

 

Deltex Medical

 

Deltex Medical manufactures and markets the CardioQ-ODMÔ system. CardioQ-ODM changes the way doctors care for surgical patients allowing them to recover faster and leave hospital sooner and in better health than they otherwise would do. The performance of the system has been validated through independently conducted, randomised controlled clinical trials and is being translated into routine clinical practice in leading hospitals around the world.

 

CardioQ-ODM comprises a monitor and a single patient disposable probe. The probe is placed into the oesophagus through either the mouth or nose and the tip positioned facing the adjacent descending aorta. A low frequency ultrasound signal, generated by the monitor, is bounced off the blood travelling down the aorta and the Doppler principle is used to determine the velocity of the blood flow, expressed in distance per cardiac cycle - 'Stroke Distance'. The monitor also calculates the amount of time that blood is flowing down the aorta as a proportion of a cardiac cycle - 'Flow Time'.

 

The monitor uses a validated proprietary nomogram to extrapolate volumetric data (Stroke Volume, Cardiac Output etc) from the directly measured flow velocity. The nomogram utilises the patient's age weight and height, effectively to estimate the size of the aorta in which the velocity of the flow is being measured. Crucially this means that any reported relative change in Stroke Volume is absolutely identical to the relative change in the directly measured flow velocity variable of Stroke Distance. CardioQ-ODM immediately and reliably identifies even very small changes in the blood flow velocity allowing doctors to intevene earlier and on smaller changes than with any other approach.

 

Intra-operative individualised Doppler guided fluid management entails insertion and focusing of the probe to obtain a baseline reading, giving a small (200 to 250 ml) fluid challenge directly into the vascular system and seeing if Stroke Volume (or Stroke Distance) increases by more than 10%. If the increase is more than 10%, repeat fluid boluses are administered until such time as the increase is less than 10%: after this no further fluid is given unless Stroke Volume falls by more than 10% - the process is designed to achieve and maintain the individual patient's optimal Stroke Volume. CardioQ-ODM is also used during surgery to guide administration of vaso-active agents such as inotropes.

 

The CardioQ-ODM helps patients by enabling doctors to reduce the complications that arise from a medical condition that is common to almost all patients having surgery and many others in intensive care or arriving in the accident and emergency department. This condition is known as hypovolaemia - a reduction in circulating blood volume - and in surgical patients arises as a direct consequence of the combined effects of pre-operative starvation, the anaesthetic agents and the blood and fluid losses associated with the surgical procedure itself. Hypovolaemia means that the body struggles to get sufficient blood to the tissues and vital organs which are consequently starved of essential oxygen. This can cause medical complications including peripheral and major organ failure, which if not dealt with quickly can lead to severe compromise or even death.

 

There are already over 2,300 CardioQ-ODMs currently in use in hospitals worldwide and distribution arrangements are in place in over 30 countries. In addition, there are currently more than 250 clinical publications on the use of the CardioQ-ODM which have repeatedly:-

 

·    Validated the results of CardioQ-ODM against known standards for measuring cardiac output

·    Proved that CardioQ-ODM works in a wide range of surgical procedures

·    Proved that CardioQ-ODM delivers 50% or more reductions in post-operative complications and 25% or more reductions in length of hospital stay: better care at lower cost.

 

The SupraQÔis an entirely non-invasive device which uses an ultrasound probe held at the base of the patient's neck to track the flow of blood in the aorta; it presents the same data as the CardioQ-ODM in a similar format and is used for taking snapshots or monitoring over short periods.

 

 


This information is provided by RNS
The company news service from the London Stock Exchange
 
END
 
 
MSCDKCDQFBDKPBK
UK 100

Latest directors dealings